Regenerator module REG-T

Descriptions
Scopes
Technical parameters

Descriptions

REG-T is installed in unattended station and regenerates the line signal in one direction without branching (linear topology of the cable communication line).

REG-T is not capable to drop channels.

The connection between the regenerator modules can be made via symmetric or optical cable communication lines.

When establishing a communication line using copper cables, the connection circuit can be two-cable or single-cable.

It provides for the mode of signal transreceiving via one cable or the mode of separation of receive and transmission signals via different cables. The separation mode allows to ensure electromagnetic compatibility with data communication analog systems.

Scopes

  • The built-in controller;
  • Interchangeable optical and SHDSL modems; Built-in sensors for external object monitoring;
  • Power supply - remote or local;
  • Access to the service communication channel;
  • Remote and local management;
  • Remains operational at the temperature of -40 to +40°C.

Technical parameters

Number of line signal directions 2
Regenerator spacing for copper cables up to 25 km
Regenerator spacing for optical fiber cables 40 to 120 km
 
Control channel

Interface RS-232
Tools dedicated software TWS V.2
 
Power supply
 
Dropped remote power supply voltage 65 V
Remote power supply current 170 mА
External power supply voltage 12, 40, 65, 90 V
Power consumption 11,05 W
 
Design
 
Corrosion-resistant waterproof case, (HxWxD) 300×305×210 mm
Degree of protection IP-65
Weight, maximum 11 kg